14. Implementing an Economizer Part 2
- www.bsdsolutions.com
- Implementing an Economizer Part 2.
- There are four basic steps to implementing an economizer into an existing HVAC system.
- The building survey gives us the cost of energy and the economizer strategy gives us the capital cost of implementing a method to save energy. ...
- An important factor effecting implementing an economizer strategy is energy cost. ...
- To calculate the amount of savings we use design weather data, ASHRAE methods and a Honeywell developed computer program to determine when we will be using an economizer effectively.
- Installing, programming and calibrating a control system for proper operation is only one part of implementing the economizer. ...
- Impact of DCV and Economizer Ventilation Strategies.
15. Re: Internal ligament inspection in economizer inlet header
- www.ndt.net
- Follow Ups Post Followup Help Re: Internal ligament inspection in economizer inlet header.
- In Reply to: Internal ligament inspection in economizer inlet header posted by : Jacques Parent on December 23, 1999 at 17:11:.
- : I am looking for any information, paper, link or past experience on internal ligament inspection in economizer inlet header.
- : Our company has experience of cracking in the economizer inlet header due to a corrosion-fatigue mechanism. ...
- : Merry Christmas : : : I am looking for any information, paper, link or past experience on internal ligament inspection in economizer inlet header. : : Our company has experience of cracking in the economizer inlet header due to a corrosion-fatigue mechanism. ...
16. Fresh Air Intake & Economizer Systems
- www.ewccontrols.com
- Fresh Air Intake & Economizer Systems.
- The EC is wired to an ERP (Economizer Relay Panel) which will open the outside air damper and turn on the fan to circulate the air to where it is needed. ...
- Model ERP Economizer Relay.
17. KIMBERLY-CLARK WYPALL L30 ECONOMIZER WIPER,WHITE (CS), Model 05812 (usahardware.com)
- www.usahardware.com
- ----> ----> KIMBERLY-CLARK WYPALL L30 ECONOMIZER WIPER,WHITE (CS).
18. Re: Internal ligament inspection in economizer inlet header
- www.ndt.net
- Follow Ups Post Followup Help Re: Internal ligament inspection in economizer inlet header.
- In Reply to: Internal ligament inspection in economizer inlet header posted by : Jacques Parent on December 23, 1999 at 17:11:.
- : I am looking for any information, paper, link or past experience on internal ligament inspection in economizer inlet header.
- : Our company has experience of cracking in the economizer inlet header due to a corrosion-fatigue mechanism. ...
- : Regards : Ed : : : I am looking for any information, paper, link or past experience on internal ligament inspection in economizer inlet header. : : Our company has experience of cracking in the economizer inlet header due to a corrosion-fatigue mechanism. ...
19. AEC - Figure 10: Effect of Malfunctioning Economizer on Compressor Operation
- www.archenergy.com
- Home » Products » ENFORMA » Virtual Tour Figure 10: Effect of Malfunctioning Economizer on Compressor Operation.
- This Diagnostic Plot shows the power draw for the roof-top unit with the economizer that doesn't allow any outside air into the building. ...
20. Buy WypAll® L30 Economizer® Wipers in Pop-Up® Box products online About WypAll® L30 Economizer® Wipers in Pop-Up® Box
- www.onlineshoppinglinks.com
- Find great buys on WypAll® L30 Economizer® Wipers in Pop-Up® Box proucts. ...
- WypAll® L30 Economizer® Wipers in Pop-Up® Box.
- WypAll® L30 Economizer® Wipers in Pop-Up® Box.
21. Wypall L30 Economizer White Wipers (6 Pop-Up Boxes of 120ea) at Arizona Tools
- www.arizonatools.com
- Wypall L30 Economizer White Wipers (6 Pop-Up Boxes of 120ea).
- Kimberly-Clark 05816 Wypall L30 Economizer White Wipers (6 Pop-Up Boxes of 120ea). ... WYPALL L30 ECONOMIZER Wipers in a POP-UP box, are great for light-duty and general purpose wiping. ...
22. Boiler Economizers
- www.cheresources.com
- Going a step further in heat integration shows how to effectively pre-heat the water entering the boiler by using the flue gas in a boiler economizer. ...
- Using an economizer setup such as this can drastically reduce the amount of fuel gas used in the boiler. Also note that finned tubes can help compensate for the poor heat transfer on the flue gas side of the economizer. ...
23. Patent 5419285: Boiler economizer and control system
- www.freepatentsonline.com
- Boiler economizer and control system.
- An increased efficiency boiler is provided, which, instead of trying to eliminate steaming in the economizer, designs the economizer to permit steaming, and a control is provided for the boiler which takes into account the heat input to the boiler as well as the water level in the steam drum and the reliability of the economizer.
- In a natural circulation boiler, comprising an evaporators, a drum connected to the evaporator, and an economizer upstream of and in fluid communication with the evaporator; said economizer including a plurality of substantially vertical multiple pass fluid flow modules in fluid communication with each other; each multiple pass module including a bottom header, a top header, and a plurality of tubes extending between and in fluid communication with said bottom header and said top header, and at least one baffle in one of said headers, so that fluid entering the multiple pass module must flow at least once upwardly from the bottom header to the top header and at least once downwardly from the top header to the bottom header before leaving the multiple pass module, the improvement comprising:.
- at least one upwardly-flowing single pass module at the downstream end of said multiple pass fluid flow modules, said upwardly-flowing single pass module including a top header and a bottom header and a plurality of tubes extending between and in fluid communication with said respective top and bottom headers, wherein fluid enters said single pass module at the bottom header, travels only up to the top header and then out of the module, said single pass module having no downwardly-directed portion, so that, if steaming occurs at the end of the economizer, it will not be trapped in a downwardly-directed tube.
- In a boiler as recited in claim 1, wherein there are two paths which the fluid leaving the economizer can take--a path into the evaporator and a bypass path in which the fluid leaving the economizer does not go into the evaporator; and further comprising a bypass valve in the bypass path, controlling the amount of fluid which takes the bypass path.
- In a boiler, comprising an evaporator including a plurality of evaporator tubes, a drum for separating water and steam; a downcomer which directs water from the drum into the evaporator tubes and a collection header which receives the output from a plurality of the evaporator tubes and directs the output from said evaporator tubes into said drum; and an economizer including an output conduit; the improvement comprising:.
- the output conduit from said economizer is in fluid communication with said collection header, so that fluid leaving said economizer can enter said drum through said collection header, thereby avoiding the need for a special feedwater pipe from the economizer to the drum.
- The present invention relates to boilers, and, in particular, to a boiler which includes an evaporator and an economizer.
- In boilers of the type referred to above, water enters the economizer at a relatively low temperature and, in the economizer section of the boiler, is usually heated to just below the boiling point. ...
- There is sometimes a problem with vaporization taking place in the economizer. In many cases, in order for the boiler to work most efficiently, the water which leaves the economizer must be close to the boiling point. However, if the water begins to boil in the economizer section, it can cause problems. ...
- With less water flow into the economizer, the water in the economizer is more likely to boil, creating the vapor lock, water hammer, and fatigue problems.
- A common solution to this problem is to put a control valve or a small orifice in the line between the economizer and the evaporator, controlling the feed water supply, in order to raise the pressure in the economizer, making it more difficult for the water to boil. ...
- Another common solution is, once boiling begins in the economizer, to cause the feed water to bypass the economizer and go directly to the evaporator. This means that the economizer is not functioning for a good part of the time the boiler is operating, thereby greatly reducing the efficiency of the boiler. It also means that the economizer cycles between hot and cold as it goes from dry to wet, which causes wear and tear on the economizer.
24. boiler economizer: Finned tubes and Finned tubing.
- www.heat-voss.com
- Economizers installed during the energy crisis of the 1970s are still operating after more than 25 years, twice the life expectancy of a typical economizer. ...
Other related topics:
Do you have a great site about Economizer? Is
your Economizer site listed here?
Would you like a prefered placement of your site in this directory?
It's easy! First place, the HTML from the box below on your page that
you would like listed in this directory.
Then use our link submission request with
your name, your contact information, and the URL of your site that has
a link to this directory. After we
verify your link to us, we'll make sure your site stays in our directory,
and we'll give it prefered placement here also.
Here is how to make a simple text link to us. Just copy the code in this
box to your website:
We can also develop a custom Guide To The Internet for your site. Please
request your own
custom Guide To The Internet.
This custom Guide To The Internet produced by
Siql. Visit us today, and find out how to get your own
custom guide to the Internet, and how to get your site
listed in our guides.
Copyright 1995-2004 by Siql. All
Rights Reserved.